画像
部品番号
メーカ
説明
パッケージ
在庫
数量
Impulse Discharge Current (8/20µs)
Tolerance
Number of Poles
Fail Short
Mounting Type
Package / Case
2093-180-SM-RPLF
Bourns Inc.

GDT 1800V 20% 3KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 1800V
  • Impulse Discharge Current (8/20µs): 3000A (3kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 2-SMD Cylinder Square End
パッケージ: 2-SMD Cylinder Square End
在庫7,344
3000A (3kA)
±20%
2
No
Surface Mount
2-SMD Cylinder Square End
2093-100-SM-RPLF
Bourns Inc.

GDT 1000V 20% 3KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 1000V
  • Impulse Discharge Current (8/20µs): 3000A (3kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 2-SMD Cylinder Square End
パッケージ: 2-SMD Cylinder Square End
在庫3,562
3000A (3kA)
±20%
2
No
Surface Mount
2-SMD Cylinder Square End
2093-200-SM-RPLF
Bourns Inc.

GDT 2000V 20% 3KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 2000V
  • Impulse Discharge Current (8/20µs): 3000A (3kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 2-SMD Cylinder Square End
パッケージ: 2-SMD Cylinder Square End
在庫5,328
3000A (3kA)
±20%
2
No
Surface Mount
2-SMD Cylinder Square End
2037-09-B5LF
Bourns Inc.

GDT 90V 5KA 2 POLE

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
パッケージ: Axial Cylinder, Radial Bend
在庫7,074
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder, Radial Bend
2037-25-B5LF
Bourns Inc.

GDT 250V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 250V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
パッケージ: Axial Cylinder, Radial Bend
在庫7,038
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder, Radial Bend
2037-60-B5LF
Bourns Inc.

GDT 600V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 600V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
パッケージ: Axial Cylinder, Radial Bend
在庫8,802
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder, Radial Bend
2037-60-B5
Bourns Inc.

GDT 600V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 600V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
パッケージ: Axial Cylinder, Radial Bend
在庫6,138
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder, Radial Bend
2037-42-B5LF
Bourns Inc.

GDT 420V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 420V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
パッケージ: Axial Cylinder, Radial Bend
在庫3,472
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder, Radial Bend
2037-35-B5LF
Bourns Inc.

GDT 350V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
パッケージ: Axial Cylinder, Radial Bend
在庫5,850
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder, Radial Bend
2037-35-B5
Bourns Inc.

GDT 350V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
パッケージ: Axial Cylinder, Radial Bend
在庫4,032
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder, Radial Bend
2037-30-B5
Bourns Inc.

GDT 300V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 300V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
パッケージ: Axial Cylinder, Radial Bend
在庫4,536
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder, Radial Bend
2037-25-B5
Bourns Inc.

GDT 250V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 250V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
パッケージ: Axial Cylinder, Radial Bend
在庫4,302
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder, Radial Bend
2037-23-B5
Bourns Inc.

GDT 230V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
パッケージ: Axial Cylinder, Radial Bend
在庫7,650
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder, Radial Bend
2037-20-B5
Bourns Inc.

GDT 200V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 200V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
パッケージ: Axial Cylinder, Radial Bend
在庫4,140
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder, Radial Bend
2035-60-BT1LF
Bourns Inc.

GAS DISCHARGE TUBE

  • Voltage - DC Spark Over (Nom): 600V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
パッケージ: Axial Cylinder
在庫4,482
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder
2035-25-B5LF
Bourns Inc.

GDT 250V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 250V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
パッケージ: Axial Cylinder, Radial Bend
在庫4,590
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder, Radial Bend
2089-350-BLF
Bourns Inc.

GDT 3500V 20% 1.5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 3500V
  • Impulse Discharge Current (8/20µs): 1500A (1.5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
パッケージ: Axial Cylinder
在庫3,526
1500A (1.5kA)
±20%
2
No
Through Hole
Axial Cylinder
2089-200-BLF
Bourns Inc.

GDT 2000V 20% 1.5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 2000V
  • Impulse Discharge Current (8/20µs): 1500A (1.5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
パッケージ: Axial Cylinder
在庫5,382
1500A (1.5kA)
±20%
2
No
Through Hole
Axial Cylinder
2089-140-BLF
Bourns Inc.

GDT 1400V 20% 1.5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 1400V
  • Impulse Discharge Current (8/20µs): 1500A (1.5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
パッケージ: Axial Cylinder
在庫3,454
1500A (1.5kA)
±20%
2
No
Through Hole
Axial Cylinder
2089-120-BLF
Bourns Inc.

GDT 1200V 20% 1.5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 1200V
  • Impulse Discharge Current (8/20µs): 1500A (1.5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
パッケージ: Axial Cylinder
在庫8,568
1500A (1.5kA)
±20%
2
No
Through Hole
Axial Cylinder
2089-100-BLF
Bourns Inc.

GDT 1000V 20% 1.5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 1000V
  • Impulse Discharge Current (8/20µs): 1500A (1.5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
パッケージ: Axial Cylinder
在庫8,136
1500A (1.5kA)
±20%
2
No
Through Hole
Axial Cylinder
2039-80-BT1LF
Bourns Inc.

GDT 800V 20% 2.5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 800V
  • Impulse Discharge Current (8/20µs): 2500A (2.5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
パッケージ: Axial Cylinder
在庫6,084
2500A (2.5kA)
±20%
2
No
Through Hole
Axial Cylinder
2039-80-B5LF
Bourns Inc.

GDT 800V 20% 2.5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 800V
  • Impulse Discharge Current (8/20µs): 2500A (2.5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
パッケージ: Axial Cylinder, Radial Bend
在庫6,534
2500A (2.5kA)
±20%
2
No
Through Hole
Axial Cylinder, Radial Bend
2039-110-BT1LF
Bourns Inc.

GDT 1100V 20% 2.5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 1100V
  • Impulse Discharge Current (8/20µs): 2500A (2.5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
パッケージ: Axial Cylinder
在庫6,012
2500A (2.5kA)
±20%
2
No
Through Hole
Axial Cylinder
2039-110-B5LF
Bourns Inc.

GDT 1100V 20% 2.5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 1100V
  • Impulse Discharge Current (8/20µs): 2500A (2.5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
パッケージ: Axial Cylinder, Radial Bend
在庫8,676
2500A (2.5kA)
±20%
2
No
Through Hole
Axial Cylinder, Radial Bend
2035-47-BT1LF
Bourns Inc.

GDT 470V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 470V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
パッケージ: Axial Cylinder
在庫4,158
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder
2035-47-B5LF
Bourns Inc.

GDT 470V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 470V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
パッケージ: Axial Cylinder, Radial Bend
在庫8,010
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder, Radial Bend
2035-35-B5LF
Bourns Inc.

GDT 350V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
パッケージ: Axial Cylinder, Radial Bend
在庫6,534
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder, Radial Bend